ORIGINAL RESEARCH |
|
Year : 2019 | Volume
: 11
| Issue : 1 | Page : 50-53 |
|
Monolithic zirconia crown does not increase the peri-implant strain under axial load
João Paulo Mendes Tribst1, Amanda Maria De Oliveira Dal Piva1, Hilton Riquieri2, Renato Sussumu Nishioka2, Marco Antonio Bottino2, Vinícius Anéas Rodrigues3
1 Department of Dental Materials and Prosthodontics, São Paulo State University, São José, Brazil; Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam, Free University Amsterdam, Amsterdam, Noord-Holland, The Netherlands 2 Department of Dental Materials and Prosthodontics, São Paulo State University, São José, Brazil 3 Department of Dental Materials and Prosthodontics, Faculty of Pindamonhangaba (FUNVIC), Pindamonhangaba, Brazil
Correspondence Address:
Dr. Amanda Maria De Oliveira Dal Piva Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam, Free University Amsterdam, Gustav Mahlerlaan 3004, 1081 LA Amsterdam, Noord-Holland The Netherlands
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/jioh.jioh_307_18
|
|
Aims: This study aimed to evaluate the influence of the crown type on the cervical microstrain around an external hexagon implant. Subjects and Methods: A dental manikin was impressed with addition-polymerizing silicone, and a hemiarch model was obtained with polyurethane resin. Then, a 3.75 mm × 11 mm implant was installed with 40 N/cm of torque in the region of element 36. Two groups were separated according to the type of crown used for rehabilitation: metal-ceramic crown (n = 10) or monolithic zirconia crown (n = 10). All crowns presented similar anatomy, with contact point in elements 35 and 37. Then, the polyurethane model was cleaned with isopropyl alcohol, and four strain gauges were bonded with cyanoacrylate adhesive in different areas (bucccal, lingual, mesial, and distal) around the implant. The crowns were installed with 20 N/cm torque, and an axial load (30 kgf) was applied in the center of the crown. Statistical Analysis: After performing 10 readings in each specimen, the data were analyzed by two-way analysis of variance and Tukey's test, all with α = 5%. Results: The results showed no statistical difference for the microstrain between the analyzed crowns (P = 0.065), and the microstrain values were different according to the area (P = 0.002): buccal (1514.9 ± 233.8) > lingual (1280.8 ± 245.5) > distal (373.2 ± 105.2) > mesial (216.7 ± 111.4). Conclusions: The crown type did not modify the microstrain in the peri-implant tissue.
|
|
|
|
[FULL TEXT] [PDF]* |
|
 |
|